Please use this identifier to cite or link to this item: http://umt-ir.umt.edu.my:8080/handle/123456789/22491
Full metadata record
DC FieldValueLanguage
dc.contributor.authorHidayati Sari Utami-
dc.contributor.authorRahman Rizky Amalia-
dc.contributor.authorNainggolan Ronald-
dc.contributor.authorArdiani Trisniaty-
dc.contributor.authorAsri Tina yUNIA-
dc.contributor.authorRaden Wasito-
dc.date.accessioned2025-07-14T07:59:40Z-
dc.date.available2025-07-14T07:59:40Z-
dc.date.issued2024-
dc.identifier.urihttp://umt-ir.umt.edu.my:8080/handle/123456789/22491-
dc.description.abstractLoop-mediated isothermal amplification (LAMP) method is useful for rapidly detecting Edwardsiella ictalurid infection, especially enteric septicemia of catfish (ESC). This study aims to investigate the LAMP method for E. ictaluri detection in ESC. This research was an experimental study using a total of 55 catfish, consisting of 5 negative controls and 50 catfish injected intraperitoneally with 0.1 mL of E. ictaluri at a concentration of 105 CFU/mL. The kidneys of three fishes were randomly selected 6, 12, 18, 24, 30, 36, 42, 48, and 54 hours after infection with E. ictaluri. In addition, samples were also collected on days 3, 5, and 7. Bacterial analysis was determined by conventional biochemistry (genus and species test), wholegenome sequencing of catfish, and LAMP amplification. All types of data obtained in this study were analyzed by descriptive statistics to compare infected and healthy catfish. The catfish were infected with E. ictaluri after 12 hours of infection according to the LAMP amplification procedure which revealed hemorrhages throughout the body, fins, protruding eyes, necrosis, inflammation of the spleen, liver, intestine, pale gills, gut, abdomen swelling, and tissue necrosis in the upper part of the head. It can be concluded that the LAMP method is more effective than the PCR method for detecting infection with E. ictaluri in catfish.en_US
dc.language.isoenen_US
dc.publisherSCIENDOen_US
dc.subjectBacteriaen_US
dc.subjectcatfishen_US
dc.subjectDiagnostic methoden_US
dc.subjectFish diseasesen_US
dc.subjectMolecular diagnosisen_US
dc.titleAPPLICATION OF LOOP-MEDIATED ISOTHERMAL AMPLIFICATION FOR Edwardsiella ictaluri DETECTION IN INDONESIA ENTERIC SEPTICEMIA OF CATFISHen_US
dc.typeOtheren_US
Appears in Collections:UMT Niche E-Book

Files in This Item:
File Description SizeFormat 
Application of Loop-Mediated Isothermal Amplification (2).pdf
  Restricted Access
1.46 MBAdobe PDFView/Open Request a copy


Items in UMT-IR are protected by copyright, with all rights reserved, unless otherwise indicated